6 AWG 4 C ALUMINUM INTERLOCKING ARMOR (AIA) POWER CABLE

XLPE/AIA/PVC 600 Volt Power Type MC Cables provide an excellent crush resistance and a cost effective alternative to installations in conduit in commercial, industrial and utility applications as well as being Sunlight, Oil and Chemical resistant. They may be used in raceways, direct buried, free air and wet or dry locations at 90°C. Permitted and approved for use per NEC Article 330 for Class 1 Div 2, Class 2 Div 2, and Class 3 Div 1 & 2 industrial hazardous locations.

APPLICATION

XLPE/AIA/PVC 600 Volt Power Type MC Cables provide an excellent crush resistance and a cost effective alternative to installations in conduit in commercial, industrial and utility applications as well as being Sunlight, Oil and Chemical resistant. They may be used in raceways, direct buried, free air and wet or dry locations at 90°C. Permitted and approved for use per NEC Article 330 for Class 1 Div 2, Class 2 Div 2, and Class 3 Div 1 & 2 industrial hazardous locations.

PART NUMBER

BWC-6-04AIAPG

STANDARDS

Rated at 90°C wet or dry locations • Meets cold bend test at -25°C • UL Type MC • UL 44, UL 1569, UL 1581, UL 1685 (Flame Exposure Test) • ICEA S-95-658 NEMA WC70 • ICEA T-29-520 210,000 BTU Flame Test • IEEE 1202/CSA FT4 70,000 BTU Flame Test • IEEE 383/UL1581 70,000 BTU Flame Test • Sunlight Resistant for CT Use

Jacket Color

BLACK

CONDUCTORS

Fully annealed bare copper Class B compressed strand per ASTM Standards

INSULATION

Flame Retardant Cross-linked Polyethylene (FR-XLPE) • Conductors are Type XHHW-2

Ground

Uninsulated, fully annealed bare copper Class B compressed strand per ASTM Standards

COLOR CODE

ICEA S-58-679 Method 4 (Black and Numbered) • Additional color coding options available;

ARMOR

Aluminum Interlocked Armor (AIA)

Assembly

Conductors are cabled together with or without nonhygroscopic fillers as required to form a round cable core

Jacket

Moisture and sunlight resistant, Flame Retardant Polyvinyl Chloride (FR-PVC) black

NO. OF CONDUCTORS

4

CONDUCTOR SIZE (AWG)

6

GROUND WIRE SIZE (AWG)

8

INSULATION THICKNES (INHCES)

0,045

INSULATION THICKNESS (MM)

1,14

DIAMETER UNDER THE ARMOR (INCHES)

0,688

DIAMETER UNDER THE ARMOR (MM)

17,48

JAKCET THICKNESS (INCHES)

0,05

JACKET THICKNESS (MM)

1,27

OVERALL DIAMETER (INCHES)

0,956

OVERALL DIAMETER (MM)

24,28

NET WEIGHT (LBS/KFT)

670

NET WEIGHT (KG/KM)

997

Premium Wire & Cable Materials for Longevity & Durability

Premium Wire & Cable Materials for Longevity & Durability

Get the products you can trust: Tested & Certified.