500 MCM – Single Conductor 35KV, MV-105, 133%/100% EPR/PVC Copper Tape Shield

35KV Shielded MV-105 cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35000 volts.

APPLICATION

35KV Shielded MV-105 cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35000 volts.

JACKET COLOR

BLACK

STANDARD

UL 1072 • UL Listed as Type MV-105 for use in accordance with NEC • AEIC CS8 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • UL 1685 UL Flame Exposure Test • IEEE 1202 Flame Test (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable

PART NUMBER

BWC-500-0135KVEPVCMV105

JACKET

Black low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape

CONDUCTORS

Class B annealed compact bare copper per ASTM

CONDUCTOR SHIELD

Extruded thermoset semi-conducting stress-control layer over conductor

INSULATION

High dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers

INSULATION SHIELD

Extruded thermoset semi-conducting polymeric layer free stripping from insulation

METALLIC SHIELD

Helically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%

CONDUCTOR SIZE (AWG/KCMIL)

500

CONDUCTOR DIAMETER (INCHES)

0,74

INSULATION THICKNESS (MILS)

420

INSULATION DIAMETER (INCHES)

2

JACKET THICKNESS (INCHES)

0,11

OVERALL DIAMETER (INCHES)

1,91

CABLE WEIGHT (LBS/KFT)

2986

AMPACITY (AMPS) CONDUIT IN AIR (90°C)

480

AMPACITY (AMPS) CONDUIT IN AIR (105°C)

535

AMPACITY (AMPS) UNDERGROUND DUCT (90°C)

465

AMPACITY (AMPS) UNDERGROUND DUCT (105°C)

500

AMPACITY (AMPS) TRAY (90°C)

510

AMPACITY (AMPS) TRAY (105°C)

565

Premium Wire & Cable Materials for Longevity & Durability

Premium Wire & Cable Materials for Longevity & Durability

Get the products you can trust: Tested & Certified.