250 MCM – Aluminum Conductor 15KV, MV-105, 133%/100% EPR/PVC Copper Tape Shield

15KV Shielded MV-105 cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15000 volts.

APPLICATION

15KV Shielded MV-105 cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15000 volts.

PART NUMBER

BWC-250-0115KVALEPMV105

STANDARDS

UL 1072 • UL Listed as Type MV-105 for use in accordance with NEC • AEIC CS8 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • IEEE 1202 Flame Test (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test • Sizes 1/0 AWG and larger are listed and marked “SunlightResistant FOR CT USE” in accordance with NEC

JACKET COLOR

BLACK

JACKET

Black low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape

CONDUCTORS

Stranded 1350 series aluminum, compact Class B stranding per ASTM

CONDUCTOR SHIELD

Extruded thermoset semi-conducting stress-control layer over conductor

INSULATION

High dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers

METALLIC SHIELD

Helically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%

CONDUCTOR SIZE (AWG/KCM)

250

CONDUCTOR DIAMETER (INCHES)

0,53

INSULATION THICKNESS (INCHES)

0,22

INSULLATION DIAMETER (INCHES)

1,01

JACKET THICKNESS (INCHES)

0,08

OVERALL DIAMTER (INCHES)

1,25

NET WEIGHT (LBS/KLFT)

869

AMPACITY (AMPS) CONDIUIT IN AIR* - 90°C

255

AMPACITY (AMPS) CONDIUIT IN AIR* - 105°C

290

AMPACITY (AMPS) UNDERGROUND DUCT** - 90°C

250

AMPACITY (AMPS) UNDERGROUND DUCT** - 105°C

270

AMPACITY (AMPS) TRAY*** - 90°C

260

AMPACITY (AMPS) TRAY*** - 105°C

290