250 MCM 3 C VFD Cable 2000V UL Type TC-ER

Three Conductor Variable Frequency Drive 2000V Cables are primarily used with AC motors controlled by pulse-width modulated inverter in VFD applications rated up to 2000 Volts. Suitable for installation in cable trays, raceways, or direct burial. They also may be installed in wet or dry locations and are permitted for use in Class I – Div 2, Class II – Div 2, and Class III – Div 1 and 2 industrial hazardous locations.

APPLICATION

Three Conductor Variable Frequency Drive 2000V Cables are primarily used with AC motors controlled by pulse-width modulated inverter in VFD applications rated up to 2000 Volts. Suitable for installation in cable trays, raceways, or direct burial. They also may be installed in wet or dry locations and are permitted for use in Class I – Div 2, Class II – Div 2, and Class III – Div 1 and 2 industrial hazardous locations.

JACKET COLOR

BLACK

CONDUCTORS

Fully annealed bare copper Class B compressed strand per ASTM B-8

STANDARDS

UL Listed as TC-ER (Exposed Run) per UL Standard 1277 as defined by NEC for 3 or more conductors • UL Type RHH or RHW-2 conductors per UL 44 • Flame Rated: IEEE (70,000 BTU), IEEE 1202/CSA FT-4, ICEA T-29-520 (210,000 BTU, 1/0 AWG and larger), Twohour Firewall • Rated 90°C wet or dry • Direct Burial • Approved for Class 1 and 2, Division 2 and Class 3, Divison 1 and 2 industrial hazardous locations per NEC • REACH Compliant

PART NUMBER

BWC-250-03VFD-3G-2KV

JACKET

Lead-free, flame-retardant polyvinyl chloride (PVC) jacket that is sunlight, weather, chemical and abrasion resistant • Meets cold bend test at -25°C and crush and impact requirements for Type MC Cable

SHIELDING

Overall 5 mil annealed bare copper tape shield, helically applied with 50% overlap and 100% coverage

GROUND(S)

3 symmetrically placed annealed bare copper conductors in direct contact with shield. Class B stranding per ASTM B-8

INSULATION

Heat and moisture resistant, chemically cross-linked polyethylene (XLPE) insulation

COLOR CODE

BLACK INSULATION WITH ICEA METHOD 4 PRINTED NUMBERS (ALL BLACK CONDUCTORS)

CONDUCTOR SIZE (AWG/KCMIL)

250

CONDUCTOR STRANDING

37W

GROUND WIRE(S) SIZE (AWG)

3#8

NOMINAL INSULATION THICKNESS (INCHES)

0,11

NOMINAL INSULATION THICKNESS (MM)

2,8

NOMINAL JACKET THICKNESS (INCHES)

0,11

NOMINAL JACKET THICKNESS (MM)

2,8

NOMINAL OVERALL DIAMETER (INCHES)

1,92

NOMINAL OVERALL DIAMETER (MM)

48,8

NET WEIGHT (LBS/MFT)

3614

AMPACITY (AMPS)

290

Premium Wire & Cable Materials for Longevity & Durability

Premium Wire & Cable Materials for Longevity & Durability

Get the products you can trust: Tested & Certified.