16 AWG 2 C UNSHIELDED SOLID – 2HR RATED FPLR DURAL RATED CIC/CI

PART NUMBER

RED

STANDARDS

Red low smoke/zero halogen FRPE (black jacket available/special order).

JACKET COLORS

Black, Red

CONSTRUCTION

Certified to the harsh requirements of the UL2196 Test for Fire Resistive Cables, the
DuraLife II Dual Rated CIC /CI cables ensure two-hour operation of critical systems in
the event of a fire. The dual rating design offers the most versatility in meeting code
survivability requirements in both in-conduit and free air installation scenarios. Description: Dual Rated CI/CIC Cable. UL/CAN (ULC) 2196 Certified/UL 1424 Listed. FHIT/
FHIT7 (ULC) System No. 28C. Low smoke, zero halogen design (LSZH).

CONDUCTORS

Conductor: Oxygen-free bare copper (OFHC), solid and/or stranded.
Insulation: Proprietary ceramifiable silicone rubber.
Assembly: Color-coded black/red leads, 3 twists/foot.
Jacket: Red low smoke/zero halogen FRPE (black jacket available/special order).

INSULATION

Oxygen-free bare copper (OFHC), solid and/or stranded.

JACKET

Proprietary ceramifiable silicone rubber.

ASSEMBLY

COMPLIANCE:
UL 1424 Listed FPLR/FPLR-CI (dual-rated) for Power-Limited Fire Alarm Circuits. Riser Rated.300V/105°C classified.
UL / CAN (ULC) Certified to UL 2196 2-hour fire rating in FHIT / FHIT7 28C.
CSA Certified FAS90; CSA Std. C22.2 No. 208-14 FT4-ST1.
UL Certified 2-hour fire rating as FPLR-CI for Free Air installed per NEC code.
UL 444 Listed “CMR/CMR-CI” as Communications Cable.
Fire alarm circuit integrity, emergency systems, and healthcare facilities (NEC Articles 760, 700 & 517).
Meets National Fire Protection Code (NFPA 70 & 72) fire alarm survivability circuit requirements.
Meets National Fire Protection Code (NFPA 130 & 502) fire alarm survivability circuit requirements.
Compliance tested to UL 1424 as suitable for use in applications requiring wet rating.
Tested for Sunlight Resistance in compliance with UL 2556 requirements.
Suitable for 2-hour certified fire-resistive applications in EMT, IMC, or Phenolic conduit systems.
UL Listed File No. E-241484. UL Fire Directory R-21213.
Splice Allowance.
RATINGS/APPROVALS:
Certified to the harsh requirements of the UL2196 Test for Fire Resistive Cables, the DuraLife II Dual Rated CIC /CI cables ensure two-hour operation of critical systems in the event of a fire. The dual rating design offers the most versatility in meeting code survivability requirements in both in-conduit and free air installation scenarios.
Description: Dual Rated CI/CIC Cable. UL/CAN (ULC) 2196 Certified/UL 1424 Listed. FHIT/ FHIT7 (ULC) System No. 28C. Low smoke, zero halogen design (LSZH).
Sizes Available: 2 conductor, 18-12 AWG unshielded; 18-14 AWG shielded.

COLOR CODE

Color-coded black/red leads, 3 twists/foot;

AWG

16

CONDUCTOR

2

STRANDING

SOLID

Shielding

UNSHIELDED

NOMINAL OD (INCHES)

0,335

NET WEIGHT (LBS/MFT)

62

NOMINAL CAPACITANCE (pf/ft)

15,3

VOLTAGE RATING (CABLE)

300

RESISTANCE (OHNS/MFT)

3,99

Premium Wire & Cable Materials for Longevity & Durability

Premium Wire & Cable Materials for Longevity & Durability

Get the products you can trust: Tested & Certified.