14 AWG 8 C UNSHIELDED SOLID – 2HR RATED MULTI-CONDUCTOR FPLR DURAL RATED CIC/CI

Certified to the harsh requirements of the UL 2196 Test for Fire Resistive Cables, the DuraLife II Dual Rated CIC /CI multi-conductor cables ensure two-hour operation of critical systems in the event of a fire. The dual rating design offers the most versatility in meeting code survivability requirements in both in-conduit and free air installation scenarios. Description: Dual Rated Multi-Conductor CI/CIC Cable. UL 2196 Certified/UL 1424 Listed. FHIT System No. 28D. Low smoke, zero halogen design (LSZH). FHIT7 System No. 28D (Canada – Non shielded only) Sizes Available: 18-12 AWG unshielded; 18-14 AWG shielded. 4/C, 6/C, and 8/C Constructions

APPLICATION

Certified to the harsh requirements of the UL 2196 Test for Fire Resistive Cables, the DuraLife II Dual Rated CIC /CI multi-conductor cables ensure two-hour operation of critical systems in the event of a fire. The dual rating design offers the most versatility in meeting code survivability requirements in both in-conduit and free air installation scenarios. Description: Dual Rated Multi-Conductor CI/CIC Cable. UL 2196 Certified/UL 1424 Listed. FHIT System No. 28D. Low smoke, zero halogen design (LSZH). FHIT7 System No. 28D (Canada – Non shielded only) Sizes Available: 18-12 AWG unshielded; 18-14 AWG shielded. 4/C, 6/C, and 8/C Constructions

PART NUMBER

BWC-CTU14A0108

STANDARDS

UL 1424 Listed FPLR/FPLR-CI (dual-rated) for Power-Limited Fire Alarm Circuits. Riser Rated. 300V/105°C classified. • UL / CAN (ULC formerly S-139) Certified to UL 2196 2-hour fire rating in FHIT / FHIT7 28C • CSA Certified to CSA Std. C22.2 No. 208; Type FAS90, 300V/90C FT4-ST1 • UL Certified 2-hour fire rating as FPLR-CI for Free Air installed per NEC code • Fire alarm circuit integrity, emergency systems, and healthcare facilities (NEC Articles 760, 700 & 517) • Meets National Fire Protection Code (NFPA 130 & 502) fire alarm survivability circuit requirements • Compliance tested to UL 1424 as suitable for use in applications requiring wet rating • Meets UL1685 and FT4/IEEE 1202 requirements • Tested for Sunlight Resistance in compliance with UL 2556 requirements • Suitable for 2-hour certified fire-resistive applications in EMT or IMC conduit systems • UL Listed File No. E-241484. UL Fire Directory R-21213 • CAFM approved

JACKET COLORS

RED

JACKET

Red low smoke/zero halogen FRPE with sequential footage markers (custom colors available/special order mins apply)

CONSTRUCTION

Conductor: Oxygen-free bare copper (OFHC), solid and/or stranded
• Insulation: Proprietary ceramifiable silicone rubber
• Assembly: Numerically printed black/red paired leads
• Jacket: Red low smoke/zero halogen FRPE with sequential footage markers (custom colors
available/special order mins apply)

CONDUCTORS

Oxygen-free bare copper (OFHC), solid and/or stranded

INSULATION

Proprietary ceramifiable silicone rubber

ASSEMBLY

Numerically printed black/red paired leads

AWG

14

CONDUCTOR

8

STRANDING

SOLID

SHIELDING

UNSHIELDED

NOMINAL OD (INCHES)

6,29

COND. RESISTANCE (OHNS/MFT)

2,57

VOLTAGE RATING (CABLE)

300

NOMINAL CAPACITANCE (pf/ft)(per pair)

17,1

Premium Wire & Cable Materials for Longevity & Durability

Premium Wire & Cable Materials for Longevity & Durability

Get the products you can trust: Tested & Certified.