10 AWG 2 C METAL CLAD W/ 1 SUPER NEUTRAL & 1 GROUND – THHN/THWN CONDUCTORS & ALUMINUM ARMOR

Super Neutral or Neutral Per Leg constructions are designed for applications where excess neutral capacity are required due to non-linear switching loads causing additive harmonic currents to be present on the neutral conductor. MC Cable is suitable for use in branch, feeder and distribution circuits in commercial, industrial, institutional and multi-residential applications. MC Cable is approves for power, lighting, control and signal circuits. MC Cable can be used in cable tray and other approved raceways and can be exposed or concealed. MC Cable can be used in places of assembly of 100 people or more, such as studios and theaters. Voltage ratings should not exceed 600V in any application, and the MC cables temperature rating is 90°C dry/75°C wet. ***MC Cable with copper conductor is suitable for use in vertical applications if installed per the requirements of the NEC as detailed in section 300.19, table 300.19(A) and section 330.30.

APPLICATION

Super Neutral or Neutral Per Leg constructions are designed for applications where excess neutral capacity are required due to non-linear switching loads causing additive harmonic currents to be present on the neutral conductor. MC Cable is suitable for use in branch, feeder and distribution circuits in commercial, industrial, institutional and multi-residential applications. MC Cable is approves for power, lighting, control and signal circuits. MC Cable can be used in cable tray and other approved raceways and can be exposed or concealed. MC Cable can be used in places of assembly of 100 people or more, such as studios and theaters. Voltage ratings should not exceed 600V in any application, and the MC cables temperature rating is 90°C dry/75°C wet. ***MC Cable with copper conductor is suitable for use in vertical applications if installed per the requirements of the NEC as detailed in section 300.19, table 300.19(A) and section 330.30.

PART NUMBER

BWC-10-02MCA/STR/SN

STANDARDS

UL Standards 83, 1569, 1581 & 2556 • IEEE 1202 vertical tray flame test, 70,000 BTU/hr. • ASTM B3, B8, B258 • NEC Articles 300.22, 330, 518.4, 520.5, 530, 545.4 & 645 • Class I Div. 2, Class II Div. 2 and Class III Div. 1 Div. 2 for hazardous locations • Federal Specification A-A59544

ASSEMBLY

• Stranded or solid soft drawn bare copper, with polyvinyl chloride (PVC) / nylon over coated type THHN/THWN insulation, with a green insulated ground conductor. The conductors are cabled together with a Mylar tape. Contact PWC Sales for available color codes.

ARMOR

Overall aluminum interlocked tape armor is applied over the assembly

CONDUCTOR SIZE CIRCUIT (NO. X AWG)

2 X 10

CONDUCTOR SIZE NEUTRAL (NO. X AWG)

1 X 8

GROUND SIZE (NO. X AWG)

1 X 10

APPROX. DIAMETER (MM)

16

APPROX. DIAMETER (INCHES)

0,63

NET WEIGHT (LBS/MFT)

260

NEUTRAL

SUPER NEUTRAL