Single Conductor 5/8KV, Shielded, MV-105 133%/100%

5/8KV Shielded MV-105 cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperatures up to 105°C and voltages up to 5000 volts in ungrounded applications and 8000 volts for grounded applications.

APPLICATION

5/8KV Shielded MV-105 cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperatures up to 105°C and voltages up to 5000 volts in ungrounded applications and 8000 volts for grounded applications.

PART NUMBER

BWC-2/0-015KVSEPMV105

STANDARD

• UL 1072 • UL Listed as Type MV-105 for use in accordance with NEC • AEIC CS8 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • IEEE 1202 Flame Test (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 per TCLP method • OSHA Acceptable • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test • Sizes 1/0 AWG and larger are listed and marked “SunlightResistant FOR CT USE” in accordance with NEC

JACKET COLOR

BLACK

INSULATION

High dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers

CONDUCTORS

Class B annealed compact bare copper per ASTM

JACKET

Black low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape

CONDUCTOR SHIELD

Extruded thermoset semi-conducting stress-control layer over conductor

INSULATION SHIELD

Extruded thermoset semi-conducting polymeric layer free stripping from insulation

METALLIC SHIELD

Helically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%

CONDUCTOR SIZE (AWG/KCMIL)

2/0

CONDUCTOR DIAMETER (INCHES)

0,38

INSULATION THICKNESS (MILS)

115

INSULATION DIAMETER (INCHES)

1

JACKET THICKNESS (INCHES)

0,06

OVERALL DIAMETER (INCHES)

0,86

CABLE WEIGHT (LBS/KFT)

728

AMPACITY (AMPS) CONDUIT IN AIR (90°C)

225

AMPACITY (AMPS) CONDUIT IN AIR (105°C)

255

AMPACITY (AMPS) UNDERGROUND DUCT (90°C)

230

AMPACITY (AMPS) UNDERGROUND DUCT (105°C)

245

AMPACITY (AMPS) TRAY (90°C)

225

AMPACITY (AMPS) TRAY (105°C)

250