400 MCM 3 C Aluminum Conductor – Aluminum MC Cable 600V Bare Ground / Jacketed

Aluminum conductor MC Cable is suitable for use as follows: Branch, feeder and service power distribution in commercial, industrial, and multi-residential buildings, power, lighting, control and signal circuits. Suitable for use in cable trays, approved raceways, concealed or exposed installations, environmental air-handling spaces, risers, as well as hazardous locations as permitted in articles 501,502,503 and 504. Priority Wire & Cable’s aluminum conductor MC Cable with Jacket is suitable for use outdoors, in wet locations, direct burial, encased in concrete, exterior/interior temporary power, as aerial cable on a messenger and hazardous locations. NOTE: Aluminum conductor MC Cable is suitable for use in vertical applications, if installed per the requirements of the NEC as detailed in section 300-19, table 300-19(a) and section 330.30.

APPLICATION

Aluminum conductor MC Cable is suitable for use as follows: Branch, feeder and service power distribution in commercial, industrial, and multi-residential buildings, power, lighting, control and signal circuits. Suitable for use in cable trays, approved raceways, concealed or exposed installations, environmental air-handling spaces, risers, as well as hazardous locations as permitted in articles 501,502,503 and 504. Priority Wire & Cable’s aluminum conductor MC Cable with Jacket is suitable for use outdoors, in wet locations, direct burial, encased in concrete, exterior/interior temporary power, as aerial cable on a messenger and hazardous locations. NOTE: Aluminum conductor MC Cable is suitable for use in vertical applications, if installed per the requirements of the NEC as detailed in section 300-19, table 300-19(a) and section 330.30.

PART NUMBER

400-03GALUM-R-MC-2/0-JKT

STANDARDS

UL 44, 83, 1569 for Type MC Cable for CT Use • NEMA WC-70/ICEA S-95-658 • IEEEE 1202 70,000 BTU/HR Vertical Tray Flame Test • ASTM B800 & B801 • NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces

JACKET COLOR

BLACK

CONDUCTORS

Compact strand 8000 series aluminum alloy conductors

JACKET

Overall black polyvinyl chloride (PVC) jacket, which is heat, moisture and sunlight resistant

INSULATION

Color coded cross-linked polyethylene XHHW-2 AA-8000 XLP insulation. A binder tape is wrapped over the insulated conductors’ assembly

COLOR CODE

240V: 3C (BLACK, WHITE, RED), 4 C (BLACK, WHITE, RED, BLUE); 480V: 3C (BROWN, ORANGE, YELLOW), 4C (BROWN, ORANGE, YELLOW, GREY)

ARMOR

Overall aluminum interlocked armor

GROUND WIRE

Bare

CONDUCTOR SIZE (AWG/KCMIL)

400

NO. OF CONDUCTORS

3

GROUND SIZE (AWG/KCMIL)

2/0

INSULATION THICKNESS (INCHES)

0,065

JACKET THICKNESS (INCHES)

0,06

DIAMETER OVER ARMOR (INCHES)

2,12

DIAMETER OVER JACKET (INCHES)

2,25

NET WEIGHT (LBS/KFT)

2 175

AMPACITY at 75°C

270

AMPACITY at 90°C

305

Premium Wire & Cable Materials for Longevity & Durability

Premium Wire & Cable Materials for Longevity & Durability

Get the products you can trust: Tested & Certified.