3/0 3 C Aluminum Conductor – Aluminum MC Cable 600V Bare Ground / Jacketed

Aluminum conductor MC Cable is suitable for use as follows: Branch, feeder and service power distribution in commercial, industrial, and multi-residential buildings, power, lighting, control and signal circuits. Suitable for use in cable trays, approved raceways, concealed or exposed installations, environmental air-handling spaces, risers, as well as hazardous locations as permitted in articles 501,502,503 and 504. Priority Wire & Cable’s aluminum conductor MC Cable with Jacket is suitable for use outdoors, in wet locations, direct burial, encased in concrete, exterior/interior temporary power, as aerial cable on a messenger and hazardous locations. NOTE: Aluminum conductor MC Cable is suitable for use in vertical applications, if installed per the requirements of the NEC as detailed in section 300-19, table 300-19(a) and section 330.30.

APPLICATION

Aluminum conductor MC Cable is suitable for use as follows: Branch, feeder and service power distribution in commercial, industrial, and multi-residential buildings, power, lighting, control and signal circuits. Suitable for use in cable trays, approved raceways, concealed or exposed installations, environmental air-handling spaces, risers, as well as hazardous locations as permitted in articles 501,502,503 and 504. Priority Wire & Cable’s aluminum conductor MC Cable with Jacket is suitable for use outdoors, in wet locations, direct burial, encased in concrete, exterior/interior temporary power, as aerial cable on a messenger and hazardous locations. NOTE: Aluminum conductor MC Cable is suitable for use in vertical applications, if installed per the requirements of the NEC as detailed in section 300-19, table 300-19(a) and section 330.30.

PART NUMBER

3/0-03GALUM-R-MC-JKT

STANDARDS

UL 44, 83, 1569 for Type MC Cable for CT Use • NEMA WC-70/ICEA S-95-658 • IEEEE 1202 70,000 BTU/HR Vertical Tray Flame Test • ASTM B800 & B801 • NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces

JACKET COLOR

BLACK

CONDUCTORS

Compact strand 8000 series aluminum alloy conductors

INSULATION

Color coded cross-linked polyethylene XHHW-2 AA-8000 XLP insulation. A binder tape is wrapped over the insulated conductors’ assembly

JACKET

Overall black polyvinyl chloride (PVC) jacket, which is heat, moisture and sunlight resistant

COLOR CODE

240V: 3C (BLACK, WHITE, RED), 4 C (BLACK, WHITE, RED, BLUE); 480V: 3C (BROWN, ORANGE, YELLOW), 4C (BROWN, ORANGE, YELLOW, GREY)

ARMOR

Overall aluminum interlocked armor

GROUND WIRE

Bare

CONDUCTOR SIZE (AWG/KCMIL)

3/0

NO. OF CONDUCTORS

3

GROUND SIZE (AWG/KCMIL)

4

INSULATION THICKNES (INHCES)

0,055

JACKET THICKNESS (INCHES)

0,05

DIAMETER OVER ARMOR (INCHES)

1,52

DIAMETER OVER JACKET (INCHES)

1,63

NET WEIGHT (LBS/KFT)

1 042

AMPACITY at 75°C

155

AMPACITY at 90°C

175

Premium Wire & Cable Materials for Longevity & Durability

Premium Wire & Cable Materials for Longevity & Durability

Get the products you can trust: Tested & Certified.