METAL CLAD FPLP – 18 AWG 4 CONDUCTOR W/ GROUND

MC-FPLP Cable is suitable for use as follows:

Wiring in Plenums, Ducts or Other Spaces Used for Environmental Air-Handling Purposes per NEC 300.22(C) & 760.135(C).
Power-Limited and Non-Power Limited fire alarm circuits, including smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devices
Class 1, Class 2, and Class 3 remote control, signaling, and power-limited circuits.
Power, lighting, control, and signal circuits.
Fished or embedded in plaster
Concealed or exposed installations.
Places of Assembly per NEC 518.4 and Theaters per NEC 520.5.
Installation in cable tray and approved raceways.
Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).

APPLICATION

MC-FPLP Cable is suitable for use as follows:

Wiring in Plenums, Ducts or Other Spaces Used for Environmental Air-Handling Purposes per NEC 300.22(C) & 760.135(C).
Power-Limited and Non-Power Limited fire alarm circuits, including smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devices
Class 1, Class 2, and Class 3 remote control, signaling, and power-limited circuits.
Power, lighting, control, and signal circuits.
Fished or embedded in plaster
Concealed or exposed installations.
Places of Assembly per NEC 518.4 and Theaters per NEC 520.5.
Installation in cable tray and approved raceways.
Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).

PART NUMBER

BWC-554687

STANDARDS

• UL 83
• UL 1063
• UL 1569
• UL 1424
• UL Online Product Guide Info – Metal-Clad Cable (PJAZ) ( www.ul.com )
• NFPA 262-2002 Standard Method of Test For Flame and Smoke of Wire and Cables for Use in AirHandling Spaces
• Federal Specification A-A59544 (formerly J-C-30B)
• IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
• NFPA 70 (National Electric Code)
• Approved for the State of Rhode Island Fire Systems
• Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems
• REACH/RoHS-2 (Chemical Limit) Compliant

MC COLOR

Red

CONSTRUCTION

MC – FPLP Cable is constructed with soft-drawn copper conductors and insulated with flame-retardant and heat-resistant PVC with an outer oil- and gasoline-resistant nylon jacket. Type THHN/THWN conductors are provided for sizes 14 AWG and 12 AWG cables; Type TFN conductors are provided for sizes 18 AWG and 16 AWG cables. The circuit conductors and a green insulated grounding conductor are cabled together and a polypropylene tape is wrapped around the assembly. Upon request, an optional Film/Foil Aluminum Laminate Shielding Tape with a tinned MC-FPLP Fire Alarm and Control APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION Red Alert Type MC – Fire Alarm and Control copper drain wire/grounding conductor is wrapped over the conductor assembly. Aluminum interlocking armor Red in color is applied over the assembly. Multiple twisted (cabled) conductor pairs/groups with optional shield(s) are available. The cable is dual rated as 90°C dry, 600 Volt Type MC and 105°C dry, 300 Volt Type FPLP cable.

CONDUCTORS

18 AWG SOLID – Soft-Drawn Copper, Type TFN Insualted Copper Singles

COLOR CODE

Black, White, Red, Blue

JACKET

Cable Jacket -insulated with flame-retardant and heat-resistant PVC with an outer oil- and gasoline-resistant nylon jacket; MC – Red Lightweight Alumium Interlocked Armor

ASSEMBLY

18 AWG SOLID Ground (Green)

AWG

18

CONDUCTOR

4

STRANDING

SOLID

NO. OF STANDS

1

INSULATION THICKNESS (INCHES)

0,015

OVERAL DIAMETER (INCHES)

0,434

NET WEIGHT

79

VOLTAGE RATING (MC)

600

VOLTAGE RATING (CABLE)

300

Premium Wire & Cable Materials for Longevity & Durability

Premium Wire & Cable Materials for Longevity & Durability

Get the products you can trust: Tested & Certified.